Our company launches the Recare Condom Width Tester, which integrates the most professional industrial touch screen, high-performance PLC control, industrial software, integrated circuits and high-precision sensing technologies. Through the dedicated collaboration of all our experts, engineers and technical workers, we ensure that the instrument we provide to you features excellent quality as well as stable and durable performance.
Adopting a photoelectric sensing measurement method, the Recare Condom Width Tester strictly complies with standard requirements, effectively ensuring the standardization and accuracy of tests. It is professionally designed for the precise width measurement of condoms. Machine operation video.
Functional Overview of condom width tester
This instrument is suitable for the precise width measurement of condoms.

Advantages of condom width tester
- Large color LCD screen displaying test results, including each measured value and statistical value.
- Equipped with a micro printer for quickly printing each measurement result, as well as statistical maximum, minimum and average values.
- Supporting a variety of practical functions such as real-time data display, automatic statistics and printing.
- Fitted with a standard RS232 interface for convenient external connection and data transmission between the system and computers.
- The system program is with ISP online upgrade function, providing personalized services for customers.
Principle
The user places the condom on the tester fixture, aligns the open end of the condom with the upper and lower fixtures of the tester, and clicks “test”. The tester automatically measures the width of the condom.
Parameter
| Width range | 30~130mm |
| Resolution | 0.01mm |
| Weight | 15Kg |
| Instrument dimensions | 300mm×300mm×500mm |
| Measurement accuracy | ±0.05mm |
Product Configuration
Main unit, Micro printer
Working Environment Requirements
- Do not use in high-humidity environments.
- Do not use in environments with strong corrosive gas, flammable or explosive substances.
- Do not use in environments with severe vibration and strong electromagnetic interference.
- Do not test objects beyond the instrument’s measuring range to avoid equipment damage.
- The power supply shall be in accordance with the product nameplate, with independent and reliable earthing. The neutral wire and earth wire shall not be mixed or connected together.
- Avoid sharing the same circuit with high-power equipment.
- Operators must read this manual carefully to understand the installation process and master all operation requirements.
Maintenance
- Cut off the power supply after the test is completed.
- Handle and move the instrument with care to prevent collision and damage.
- Follow the product nameplate for standard power supply use and ensure reliable earthing. The neutral wire and earth wire shall not be mixed or connected together. Avoid sharing the same circuit with high-power equipment.
- Keep the instrument clean and cover the entire unit with a dust cloth when not in use.
- On the basis of being familiar with this manual and electrical principles, operators may perform routine maintenance and troubleshooting with the cooperation of the manufacturer’s maintenance personnel. The manufacturer’s personnel must cut off the power supply before overhauling the instrument; live operation is strictly forbidden.
- Conduct precision calibration at intervals in accordance with relevant specifications.
- No private disassembly by the user is allowed.
Special Notes
- Wipe the measuring head, lower anvil and other parts in contact with the sample with alcohol cotton balls before each operation.
- Ensure the surrounding environment meets the requirements when measuring samples; otherwise, the test accuracy will be affected.
- This is a high-precision testing instrument; all operations must be performed gently.
FAQ
Q1.Could the language of the operating system of condom width tester be changed??
A:Yes, we can change the language of the operating system before leaving the factory. You can confirm with us before placing an order.
Q2. What is the accuracy calibration interval?
A:The accuracy calibration interval is subject to the relevant specifications. (We recommend performing the calibration every six months to one year.)
Q3. What about sensor damage and replacement?
A: The displacement sensor of this Condom Width Tester is replaceable, and only the sensor models designated by the manufacturer are allowed for replacement. The sensor is uniquely matched with the machine’s control board and cannot be interchanged with other sensors of the same type. Each sensor has a corresponding set of calibration data stored in the control board. Random sensor replacement will lead to inaccurate measurement data. Therefore, please use the original standard sensors provided by the manufacturer, or ensure the new sensor is calibrated before use.
Q4. Are operation manuals and video tutorials of Condom Width Tester available?
A: Yes, we can provide operation manuals and instructional videos in the local language for our customers.
Q5. Can your technical staff go overseas for on-site installation, debugging and training?
A: Our technical team is available for overseas business trips to provide on-site services including installation, debugging and training. The customer shall be responsible for covering all round-trip transportation and accommodation expenses of our staff.
Q6. What is the product warranty period?
A: The warranty period is 12 months (one year), which is subject to the warranty terms of the accessory components adopted in the equipment.
Q7. Is there a bulk purchase discount?
A: A 10% discount is offered for orders of 5 or more machines.
Q8. What payment terms do you accept?
A: We adopt T/T payment terms: 30% deposit in advance, and the remaining 70% balance to be paid against the copy of Bill of Lading (B/L).
Q9. What is the production and delivery lead time?
A: For small quantity orders, the delivery can be arranged within 15-20 working days; for bulk orders, the delivery time is 30-45 working days.